Skip to Main Content »

Need Help? Call Our Team: 01257 441590 Email Us: sales@sonicfs.com
Supply, Installation & Maintenance

You're currently on:

More Views

Ziton ZP3 Network interface board

Email to a Friend

Be the first to review this product

Availability: In stock.

£182.00
Add Items to Cart
OR

Quick Overview

ZP3AB-NET1 - Network board optional facility card

Ziton ZP3 Network Interface Board

ZP3AB-NET1 - Network board optional facility card

Enables simple connection for Ziton ZP3 networks The Ziton ZP3AB-NET1 enables Ziton ZP3 control panels to be connected together to form networks. The interface card is attached directly onto the ZP3 main control board inside the panel enclosure. Up to 64 standalone control panels can be linked to form the Ziton ZP network allowing the integration of over 32,000 system devices.

Networks can be designed as peer to peer systems where all control panels are connected to form a single coordinated fire detection and alarm system. Each panel controls its own devices and displays its own systems information, but is capable of cross panel cause and effect operation. The Ziton ZP3AB-NET1 network board also enables hierarchical networks to be easily configured, where one or more control panels can be assigned as masters displaying complete system status.

RS485 protocol Communication between Ziton ZP3 fire alarm panels operates by RS 485 protocol, over twisted screened pair wiring. Total cable length, throughout the network can be up to a maximum of 2 kilometres. On larger sites, where wiring runs to remote systems may exceed this maximum, cable lengths can be extended by the addition of RS485 booster units or optical fibre connection. Designed to provide flexible system configuration, system wiring can be daisy chained or teed off with spurs. Network connections are in data quality cable with a minimum core diametre of 0.5 mm. Jumper terminating switches are provided on all network interface boards, which are set at the system commissioning stage.

Cost effective options The Ziton ZP3AB-NET1 network board is part of the range of optional facility boards, which can be added, cost effectively to any ZP3 control panel, in order to provide extra facilities that may not be a requirement of every system. Housed within the ZP3 fire panel, options can simply be added during panel manufacture to meet particular specifications, or subsequently fitted on site should a particular requirement become necessary during the life of the system.

Standard Features:

  • Up to 64 panel networking
  • Housed inside main panel enclosure
  • Complete cross panel communications
  • Inter panel cause and effect operation
Model No ZP3AB-NET1

Standard Delivery - 3 Working Days (Orders must be placed before 11am Mon - Fri excluding bank holidays and weekends).

Deliveries can only be made to UK mainland addresses.

All deliveries on behalf of Sonic Fire & Security Ltd must be signed for by the person placing the order or their agent, and goods can only be delivered to the address stated on the order.

All delivery charges are clearly stated on checkout. If you wish to order multiple items then delivery may be reduced, please contact us.

Sonic Fire & Security Ltd will confirm delivery date by e-mail. It is the customer

While Sonic Fire & Security Ltd shall make every effort to effect fast delivery they shall not be held liable for lost profits, loss of business or any other consequential, special, indirect or punitive damages, or any claim by a third party.

All orders from Sonic Fire & Security Ltd may be returned within 30 days for a full refund provided they are returned as new and complete including original packaging, accessories and manuals etc.

All returned merchandise must be in the original packaging including manuals, accessories, cables, etc. All free items must be returned together with purchased items in order to receive a full refund. Any shipping and/or handling charges on the original order cannot be refunded. At our discretion, we may levee a restocking fee of 15% of the cost of new items returned. Damaged or incomplete items which cannot be resold will severely affect your refund. Any vouchers or gift certificates earned by a returned order will be voided, and the voucher amount will be charged to any order to which it was applied.

Sonic Fire & Security Ltd is not responsible for shipping costs or damage on returned items. Units to be returned should be packed carefully. Please be advised that packages sent by normal Postal Service cannot be tracked to ensure delivery. Since Sonic Fire & Security Ltd cannot provide credit for a return without confirming its receipt, we recommend that you use a delivery service that can be tracked and or insured.

The customer should inspect the goods on receipt and within 10 days advise Sonic Fire & Security Ltd of any shortages or defect in either material or workmanship. Customers have the right to cancel orders within 7 working days without giving a reason. The customer must pay for the cost of returning the goods. This does not affect your statutory rights as a consumer.

 

Compare Products

You have no items to compare.

My Cart

You have no items in your shopping cart.

Large Savings
Need Help?
Click here to view the full range
Click here for Fire Installation information
Click here for Fire Maintenance information
Click here for Security Installation information
Click here for Security Maintenance information
Click here for Sub-contract information