Skip to Main Content »

Need Help? Call Our Team: 01257 441590 Email Us: sales@sonicfs.com
Supply, Installation & Maintenance

You're currently on:

More Views

Ziton ZP3 8 way monitored alarm driver board

Email to a Friend

Be the first to review this product

Availability: In stock.

£273.00
Add Items to Cart
OR

Quick Overview

ZP3AB-MA8 - Eight way programmable sounder driver board

Ziton ZP3 8 way monitored alarm driver board

ZP3AB-MA8 - Eight way programmable sounder driver board

Eight individually programmable sounder circuits The Ziton ZP3AB-MA8 is one of a series of additional, auxiliary boards designed to extend the Ziton ZP3 panel standard range of input/output facilities. Driver boards are modular in design, and are mounted inside the Ziton ZP3 panel enclosure, by means of a ZP3-AC1 auxiliary chassis.

Up to three driver boards can be fitted into a Ziton ZP3 panel. They may be all of a single type, or any combination from the I/O module range. The addition of auxiliary boards can increase the panel outputs to a maximum of 72 all housed within the ZP3 enclosure. Further driver boards can be added to a system, accommodated in a remote control cabinet, usually located alongside the Ziton ZP3 fire panel. Various sized cabinets are available, designed to match the control panel enclosure. Each ZP3 panel has the ability to operate up to 896 outputs, of which 768 are programmable.

The Ziton ZP3AB-MA8 is designed to extend a standard ZP3 control panel by a further 8 alarm outputs, each individually programmable. The maximum power rating for each sounder circuit is 1 Amp.

Open and short circuit monitoring Wiring is monitored for both open and short circuit faults and sounders must be polarised and wired across the positive and negative alarm circuit conductors. Circuits are terminated with end of line monitoring resistors, tee offs and spurs are not allowed. Power to operate modules is usually provided internally from the control panel, but terminals on the board are provided for the connection of external power supply units.

Individual alarm indication Each eight way sounder board is allocated an address by switch settings provided on the PCB. Individual outputs (within the board address) are programmed in the system's cause and effect software set up. Visual indication of alarm active and output fault is given by LEDs for each output. Housed within the ZP3 panel, options can simply be added during panel manufacture to meet individual specifications, or subsequently fitted on site should a particular requirement become necessary during the life of the system.

Standard Features:

  • Eight programmable sounder circuits
  • Up to three modules within panel enclosure
  • 1 amp per circuit sounder loading
  • LED indication for each output
Model No ZP3AB-MA8

Standard Delivery - 3 Working Days (Orders must be placed before 11am Mon - Fri excluding bank holidays and weekends).

Deliveries can only be made to UK mainland addresses.

All deliveries on behalf of Sonic Fire & Security Ltd must be signed for by the person placing the order or their agent, and goods can only be delivered to the address stated on the order.

All delivery charges are clearly stated on checkout. If you wish to order multiple items then delivery may be reduced, please contact us.

Sonic Fire & Security Ltd will confirm delivery date by e-mail. It is the customer

While Sonic Fire & Security Ltd shall make every effort to effect fast delivery they shall not be held liable for lost profits, loss of business or any other consequential, special, indirect or punitive damages, or any claim by a third party.

All orders from Sonic Fire & Security Ltd may be returned within 30 days for a full refund provided they are returned as new and complete including original packaging, accessories and manuals etc.

All returned merchandise must be in the original packaging including manuals, accessories, cables, etc. All free items must be returned together with purchased items in order to receive a full refund. Any shipping and/or handling charges on the original order cannot be refunded. At our discretion, we may levee a restocking fee of 15% of the cost of new items returned. Damaged or incomplete items which cannot be resold will severely affect your refund. Any vouchers or gift certificates earned by a returned order will be voided, and the voucher amount will be charged to any order to which it was applied.

Sonic Fire & Security Ltd is not responsible for shipping costs or damage on returned items. Units to be returned should be packed carefully. Please be advised that packages sent by normal Postal Service cannot be tracked to ensure delivery. Since Sonic Fire & Security Ltd cannot provide credit for a return without confirming its receipt, we recommend that you use a delivery service that can be tracked and or insured.

The customer should inspect the goods on receipt and within 10 days advise Sonic Fire & Security Ltd of any shortages or defect in either material or workmanship. Customers have the right to cancel orders within 7 working days without giving a reason. The customer must pay for the cost of returning the goods. This does not affect your statutory rights as a consumer.

 

Compare Products

You have no items to compare.

My Cart

You have no items in your shopping cart.

Large Savings
Need Help?
Click here to view the full range
Click here for Fire Installation information
Click here for Fire Maintenance information
Click here for Security Installation information
Click here for Security Maintenance information
Click here for Sub-contract information