Skip to Main Content »

Need Help? Call Our Team: 01257 426466 Email Us: sales@sonicfs.com
Supply, Installation & Maintenance

You are currently on:

    • Product Ziton ZP700 Recessed sensor base successfully added to compare list
    • Product Ziton ZP700 Recessed sensor base successfully added to compare list
    • Product Ziton ZP700 Recessed sensor base successfully added to compare list
    • Product Ziton ZP700 Recessed sensor base successfully added to compare list
    • Product Ziton ZP700 Recessed sensor base successfully added to compare list
    • Product Ziton ZP700 Recessed sensor base successfully added to compare list

Ziton ZP700 Recessed sensor base

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Ziton ZP700 Recessed sensor base

Be the first to review this product

Availability: In stock.

£ 9.00
Add Items to Basket
OR

Quick Overview

ZP7-RB1 - Analogue sensor base - recessed

Product Description

Ziton ZP700 Recessed sensor base


ZP7-RB1 - Analogue sensor base - recessed


Semi recessed fixing - The Ziton ZP7-RB1 sensor base, allows ZP700 analogue sensors to be semi recessed into ceiling tiles, when installed into buildings with suspended ceilings. The sensor low profile is further reduced without any increased difficulty in wiring termination.


Simply installed the ZP7-RB1 base moulding passes through a clearance hole in the ceiling tile, where it is clamped between a retaining flange on the underside of the base moulding and a threaded collar, tightened down from above. Tile sections of up to 25mm can be accommodated.


Common to all the ZP700 range, the Ziton ZP7-RB1 base allows removal and replacement of sensors without the disconnection of wiring from terminals. Sensors plug into the base units with a simple twist and lock action, allowing quick and easy removal for cleaning and servicing, or reselection of device type should the usage of the protected area change.


Robust wiring terminals - Ziton ZP7-RB1 Bases feature robust wiring terminals with captive clamping washers to ensure secure wiring termination. Terminals are provided inside the moulding for loop connections and the termination of cable screening. Provision is also made for the connection of a remote LED when required.


Automatic locking option - In order to prevent unauthorised removal of a device from its base, an automatic locking breakout is incorporated into all sensor mouldings. If the breakout is removed, sensors can then only be released from their bases by use of a Ziton detector head picker (Z-PH-2). The locking facility is an easily applied option, often taken on site, at the system commissioning stage.


Matching spaces for address labels are provided on sensor and base mouldings - ensuring that when removed, devices are replaced in the correct location. The address number facility also enables sensors to be easily identified when viewed from
floor level.



ZP7-RB1 Standard Features:



  • Enhances sensor low profile

  • Common to all Z700 series detectors

  • Automatic locking option

  • Address identification label

  • Ease of installation


Additional Information

Model No ZP7-RB1
 

My Basket

You have no items in your shopping basket.

Compare Products - 34 Items

  1. Remove This Item Ziton ZP3 1 loop analogue control panel, 230V, EN54 approved
  2. Remove This Item Ziton ZP3 2 loop analogue control panel, 230V, EN54 approved
  3. Remove This Item Ziton ZP3 4 loop analogue control panel, 230V, EN54 approved
  4. Remove This Item Ziton ZP3 Network interface board
  5. Remove This Item Ziton ZP3 Class A network loop card
  6. Remove This Item Ziton ZP3 Serial communication board (RS232)
  7. Remove This Item Ziton ZP3 8 way monitored alarm driver board
  8. Remove This Item Ziton ZP3 8 way relay board
  9. Remove This Item Ziton ZP3 8 way input board
  10. Remove This Item Ziton ZP3 24 way transistor output board
  11. Remove This Item Ziton ZP3 Serial control bus interface board
  12. Remove This Item Ziton ZP3 Integral printer for ZP3 panel
  13. Remove This Item Ziton ZP3 Integral modem on ZP3-ACC-MP mounting chassis
  14. Remove This Item Ziton ZP3 Auxiliary chassis plate for MA8 / RL8 / MIP8 / OP24 / NLM (3 max)
  15. Remove This Item Ziton ZP3 Flushing collar for ZP3 panel
  16. Remove This Item Ziton 1 loop ZP3 motherboard on chassis
  17. Remove This Item Ziton 4 loop ZP3 motherboard on chassis
  18. Remove This Item Ziton CPU for ZP3 (1MB)
  19. Remove This Item Ziton Replacement ZP3 Lite keypad
  20. Remove This Item Ziton Replacement 4 key pack for ZP3 panel
  21. Remove This Item Ziton Replacement ZP3 printer roll
  22. Remove This Item Ziton Replacement ZP3 printer ribbon
  23. Remove This Item Ziton ZP3 address labels 1001-1127
  24. Remove This Item Ziton ZP3 address labels 2001-2127
  25. Remove This Item Ziton ZP3 address labels 3001-3127
  26. Remove This Item Ziton ZP3 address labels 4001-4127
  27. Remove This Item Ziton ZP700 Optical sensor
  28. Remove This Item Ziton ZP700 Heat sensor (ZP3 Version 1.XX & 2.XX software streams)
  29. Remove This Item Ziton ZP700 Heat sensor (ZP3 Version 3.XX software stream)
  30. Remove This Item Ziton ZP700 Combination sensor (optical & heat)
  31. Remove This Item Ziton ZP700 Ionisation sensor
  32. Remove This Item Ziton ZP700 Surface mounting sensor base
  33. Remove This Item Ziton ZP700 Recessed sensor base
  34. Remove This Item Ziton ZR454 Wireless Alarm Sounder
Clear All
Click here for information regarding our prices
Click here for Fire Installation information
Click here for Fire Maintenance information
Click here for Security Installation information
Click here for Security Maintenance information
Click here for Sub-contract information