Z6BS-1 Conventional Detector Base

Product Description

Ziton Z6BS-1 Conventional Surface Mount Detector Base


Z6BS-1 Conventional Detector Base


Simple twist and lock action The Ziton Z6-BS1 detector base allows any Z600 conventional detector to be removed or replaced without disconnecting wiring from detector terminals.


Ziton Z600 detectors plug into the Z6BS-1 base units with a simple twist and lock action, allowing quick and easy removal for cleaning and servicing, or reselection of detector type should the usage of the protected area change.


Designed for systems where head out continuity is not a requirement, detector line monitoring is provided by a suitable end of line resistor, connected across the out terminals of the final device in the circuit.



Robust wiring terminals Forming an integral part of the overall detector assembly, the Ziton Z6BS-1 base is provided with slots for screw fixing to either surface wiring plates, or conduit boxes with screw fixing centres between 50mm and 90 mm.


Ziton Z6BS-1 bases feature robust wiring terminals with captive clamping washers to ensure secure wiring termination. The bases are of shallow design with ample space to accommodate cables of all types. Terminals are provided inside the moulding for the connection of a remote LED when required.



Automatic locking In order to prevent unauthorised removal of a detector from its base, an automatic locking breakout is incorporated into the interior of all detector mouldings. If the breakout is removed, detectors can then only be released from their bases by use of a Ziton detector head picker (Z-PH-2). The locking facility is an easily applied option, often taken on site, at the system commissioning stage.


For systems complying with the recomendations of BS5839 Pt1, where the removal of a detector from it's base must not effect the operation of devices wired further down the line, the Z6-BS5 base should be installed.




Ziton Z6BS-1 Standard Features:



  • Common to all Z600 series detectors

  • Automatic locking option

  • Ease of installation

Additional Information

Model No Z6BS-1