Skip to Main Content »

Need Help? Call Our Team: 01257 426466 Email Us: sales@sonicfs.com
Supply, Installation & Maintenance

You are currently on:

    • Product Ziton ZP7 Weatherproof surface mounting red analogue callpoint (IP67) successfully added to compare list

Ziton ZP7 Weatherproof surface mounting red analogue callpoint (IP67)

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Ziton ZP7 Weatherproof surface mounting red analogue callpoint (IP67)

Be the first to review this product

Availability: In stock.

£ 148.00
Add Items to Basket
OR

Quick Overview

ZP787-2 - Addressable waterproof callpoint

Product Description

Ziton ZP7 Weatherproof surface mounting red analogue callpoint (IP67)


ZP787-2 - Addressable waterproof callpoint


IP67 rating - The Ziton ZP787-2 is a waterproof, surface mounting, call point providing a manual means of initiating a fire alarm. Rated at IP67, the Ziton ZP787-2 unit is designed for outdoor applications or in systems where the ingress of water can be expected, for example where hygiene requirements demand regular washing or hosing down of the protected area.


Complying with EN 54 Part 11, the Ziton ZP787-2 callpoint is suitable for installations meeting the recommendations of most local codes (e.g. BS 5839 Part 1). The Ziton ZP787-2 callpoint is approved by several international approval bodies.


Intended to provide a rugged, reliable means of initiating a fire alarm, the Ziton ZP787-2 call point can be particularly useful where a manual means of activation, has to be provided outdoors. The enclosure is constructed of red high impact plastic, clearly labeled fire.


Coated glass element - The Ziton ZP787-2 unit is operated by breaking a frangible glass element with finger pressure. Glass elements have clear vinyl coatings on the front surface to prevent operator injury and to inhibit the release of loose fragments, as the glass is broken.


Installed as part of the ZP3 analogue addressable system, up to 127 devices (call points, sensors and interface units) can be connected to each of the control panel loops. All loop devices incorporate switch settings enabling them to be assigned a
unique address, which is polled by the panel every two seconds.


Special test key - System testing is carried out by using a special test key which is inserted into a slot in the base of the call point moulding, the glass element drops allowing the device to operate. For locations where accidental or malicious use may occur, the operation of the unit can be restricted by the addition of a hinged, clear polycarbonate, front cover (Z-CPC). For further protection the cover can be secured by a breakable seal (Z-CCS-1). In use the seal must be broken, prior to raising the cover.


ZP787-2 Standard Features:



  • IP 67 rating

  • Addressable

  • Complies with BS 5839 Part 2 and EN 54 Part 11

  • System test facility via test key

  • Operated by finger pressure


Additional Information

Model No ZP787-2
 

My Basket

You have no items in your shopping basket.

Compare Products - 43 Items

  1. Remove This Item Ziton ZP3 1 loop analogue control panel, 230V, EN54 approved
  2. Remove This Item Ziton ZP3 2 loop analogue control panel, 230V, EN54 approved
  3. Remove This Item Ziton ZP3 4 loop analogue control panel, 230V, EN54 approved
  4. Remove This Item Ziton ZP3 Repeater panel, 24V (LCD & controls)
  5. Remove This Item Ziton ZP3 Network interface board
  6. Remove This Item Ziton ZP3 Class A network loop card
  7. Remove This Item Ziton ZP3 Serial communication board (RS232)
  8. Remove This Item Ziton ZP3 8 way monitored alarm driver board
  9. Remove This Item Ziton ZP3 8 way relay board
  10. Remove This Item Ziton ZP3 8 way input board
  11. Remove This Item Ziton ZP3 24 way transistor output board
  12. Remove This Item Ziton ZP3 Serial control bus interface board
  13. Remove This Item Ziton ZP3 Integral printer for ZP3 panel
  14. Remove This Item Ziton ZP3 Integral modem on ZP3-ACC-MP mounting chassis
  15. Remove This Item Ziton ZP3 Auxiliary chassis plate for MA8 / RL8 / MIP8 / OP24 / NLM (3 max)
  16. Remove This Item Ziton ZP3 Flushing collar for ZP3 panel
  17. Remove This Item Ziton 1 loop ZP3 motherboard on chassis
  18. Remove This Item Ziton 4 loop ZP3 motherboard on chassis
  19. Remove This Item Ziton CPU for ZP3 (1MB)
  20. Remove This Item Ziton Replacement ZP3 Lite keypad
  21. Remove This Item Ziton Replacement 4 key pack for ZP3 panel
  22. Remove This Item Ziton Replacement ZP3 printer roll
  23. Remove This Item Ziton Replacement ZP3 printer ribbon
  24. Remove This Item Ziton ZP3 address labels 1001-1127
  25. Remove This Item Ziton ZP3 address labels 2001-2127
  26. Remove This Item Ziton ZP3 address labels 3001-3127
  27. Remove This Item Ziton ZP3 address labels 4001-4127
  28. Remove This Item Ziton ZP700 Optical sensor
  29. Remove This Item Ziton ZP700 Heat sensor (ZP3 Version 1.XX & 2.XX software streams)
  30. Remove This Item Ziton ZP700 Heat sensor (ZP3 Version 3.XX software stream)
  31. Remove This Item Ziton ZP700 Combination sensor (optical & heat)
  32. Remove This Item Ziton ZP700 Ionisation sensor
  33. Remove This Item Ziton ZP700 Surface mounting sensor base
  34. Remove This Item Ziton ZP700 Recessed sensor base
  35. Remove This Item Ziton Deep mounting for ZP7-SB1 base
  36. Remove This Item Ziton ZP7 Flush mounting red analogue callpoint c/w EN54 marking
  37. Remove This Item Ziton ZP7 Callpoint Red surface box
  38. Remove This Item Ziton ZP7 Callpoint EN54 universal glass no logo (10 pack)
  39. Remove This Item Ziton ZP7 Callpoint Resettable element (EN54 marking)
  40. Remove This Item Ziton ZP7 Callpoint Pack of 10 test keys
  41. Remove This Item Ziton ZP7 Callpoint Transparent protective hinged cover
  42. Remove This Item Ziton ZP7 Weatherproof surface mounting red analogue callpoint (IP67)
  43. Remove This Item Ziton ZR454 Wireless Alarm Sounder
Clear All
Click here for information regarding our prices
Click here for Fire Installation information
Click here for Fire Maintenance information
Click here for Security Installation information
Click here for Security Maintenance information
Click here for Sub-contract information